Home > ELECTRICAL > LIGHTING & CEILING FANS > LIGHT FIXTURES > LIGHTING - RECESSED
Sort By:
1 2 3
Powerzone 30000-3L Recessed Light Bar Hanger Halo 301P Open Recessed Light Trim Halo 401P Open Recessed Light Trim
Two piece hanger bar for 24" maximum joist spacing. Made of steel with a galvanized finish. Open recessed  trim ring, 7-1/4" OD, for use with 6" housings: Halo model numbers (Orgill SKU numbers): H7T (284.2474), H7RT (942.0381) and SHALLOW H27T (989.1672). Sleeved. Open recessed  trim ring, 7-1/4" OD, for use with 6" housings: Halo model numbers (Orgill SKU numbers), H7T (540.1815), and SHALLOW H27T (989.1672). H7RT (942.0381). Sleeved.
FIXT RCSD CEIL WH SF RING     Halo H7ICT Recessed Housing Halo H7ICAT Recessed Housing
Recessed ceiling light. Tapered baffle. Minimizes glare and reduces ceiling brightness. The baffles narrow the focus of the down lighting beam and many are used with reflector lamps. Contoured tapered sides of coilex baffle for use with reflector lamps. Coil spring retention. Self-flanged trim ring sized to hide gaps caused by construction tolerances. Compatible with halogen, incandescent, LED or CFL lamps. For use with 120 volt Incandescent lamps. Aluminum construction for greater heat dissipation. For installations where housing will be in direct contact with ceiling insulation. Integral thermal protector guards against misuse of insulation materials and improper lamping. Adjustable socket bracket assures proper and consistent lamp positing. Junction box is listed for through branch circuit wiring and has seven 1/2" knockouts. Slide-N-Slide connectors allow non-metallic sheathed cable to be installed without removing knockouts. Pre-installed captive bar hangers allow housing to be positioned at any point within a 24" joist span. Can be field shortened for 12" joist.  Installation: 7-1/2" height allows use in 2 x 8 joist construction. Housing accommodates ceilings up to 2" thick. Requires 6-1/2" ceiling opening. Listings: UL Damp Locations. UL Feed Through. UL Listed for direct contact with insulation. CSA Certified. IP Rated. Air-tite fixture sealed and gasketed to prevent airflow between attic and living areas. For installations where housing will be in direct contact with ceiling insulation. Integral thermal protector guards against misuse of insulation materials and improper lamping. Adjustable socket bracket assures proper and consistent lamp positing. Junction box is listed for through branch circuit wiring and has seven 1/2" knockouts. Slide-N-Slide connectors allow non-metallic sheathed cable to be installed without removing knockouts. Pre-installed captive bar hangers allow housing to be positioned at any point within a 24" joist span. Can be field shortened for 12" joist.  Installation: 7-1/2" height allows use in 2 x 8 joist construction. Housing accommodates ceilings up to 1" thick. Requires 6-1/2" ceiling opening. Listings: UL Damp Locations. UL Feed Through. UL Listed for direct contact with insulation. CSA Certified. IP Rated.
Halo 300P Open Recessed Light Trim TRIM FIXT FULL BFFL WH/BLK 6IN Halo 5000P Open Splay Trim
Open recessed  trim ring, 7-1/4" OD, 3-7/8" ID, for use with 6" housings: Halo model numbers (Orgill SKU numbers), H7ICT (552 4277), H71CAT (854 3951), H7RIC (025 9697). Sleeved. Black baffle and white trim. 6" baffles. Torsion spring retention. Socket supporting baffle. Slightly oversized ring expands coverage of ceiling cut-out errors. Diameter of 6-1/2", white trim for use with 5" incandescent rounds. Non-insulated or insulated housings. 75 watt maximum. Bulb sold separately. For use with 5" housings: Halo model numbers (Orgill SKU numbers), H5T (424.1535), H5ICAT (651.3956) and H5RT (635.6182).
Halo H5ICAT Recessed Housing Coilex Halo 310P Baffle Trim Coilex Halo 310W Baffle Trim
For installations where housing will be in direct contact with ceiling insulation. Air-tite fixture sealed and gasketed to prevent airflow between attic and living areas. Integral thermal protector guards against misuse of insulation materials and improper lamping. Junction box is listed for through branch circuit wiring and has seven 1/2" knockouts and four Romex knockouts with integral strain relief. Pre-installed captive bar hangers allow housing to be positioned at any point within a 24" joist span. Can be field shortened for 12" joist. Installation: 7-1/2" height allows use in 2 x 8 joist construction.  Housing accommodates ceilings up to 1-3/8" thick. Requires 5-3/4" ceiling opening. Listings: UL Damp Locations. UL Feed Through. UL Listed for direct contact with insulation. CSA Certified. IP Rated. Trim ring with phenolic baffle, 7-1/4" OD, for use with 6" housings: Halo model numbers (Orgill SKU numbers), H7T (540.1815), H71CT (552.4277), H71CAT (854.3951), H7RT (942.0381), H7RIC (025.9697) and SHALLOW H27T (989.1672). Sleeved. Trim ring with phenolic baffle, 7-1/4" OD, for use with 6" housings: Halo model numbers (Orgill SKU numbers), H7T (540.1815), H71CT (552.4277), H71CAT (854.3951), H7RT (942.0381), H7RIC (025.9697) and SHALLOW H27T (989.1672). Sleeved.
Halo 70PS Recessed Light Shower Trim Halo H7 Recessed Housing Halo H750ICAT Recessed Housing
Wet location and AIR-TITE listed white trim with frosted Albalite Lens. 8" OD, for use with 6" housings: Halo model numbers (Orgill SKU numbers): H7T (284.2474), H7RT (942.0381), and SHALLOW H27T (989.1672). Sleeved. For installations in non-insulated ceilings or where insulation can be kept 3" from housing. Integral thermal protector guards against misuse of insulation materials and improper lamping. Adjustable socket bracket allows the use of different lamp types and sizes as well as proper and consistent lamp posting. Junction box is listed for through branch circuit wiring and has seven 1/2" knockouts and four Romex knockouts with integral strain relief. Plaster frame includes locking screw for hanger bars and cut outs for crimping hanger bars into position. Pre-installed captive bar hangers allow housing to be positioned at any point within a 24" joist span and can be field shortened for 12" joist. Installation: 7-1/2" height allows use in 2 x 8 joist construction.  Housing accommodates ceilings up to 2" thick. Requires 6-1/2" ceiling opening. Listings: UL Damp Locations. UL Feed Through. CSA Certified. IP Rated. For use with Halo H7 LED 600 Series and 900 Series LED modules. Rated for direct contact with air-permeable insulation in insulated ceilings, may also be used in non insulated ceilings. Air-tite fixture sealed and gasketed to prevent airflow between unconditioned areas and living areas. Rated for 15 watts maximum. 10-1/2" length x 7-1/2" width x 7-1/2" height with 1/2" plaster lip. Ceiling cutout: 6-1/2".
Halo H750RICAT Remodel Recessed Housing Powerzone TRIM201-BN (MTM3) Baffle Trim Halo H7 Remodel Recessed Housing
For use with Halo H7 Collection 600 900 Series LED modules, designed for remodel into insulated ceilings and can be in direct contact with ceiling insulation. AIR-TITE housing design prevents airflow between attic and living areas. Single wall aluminum housing. Installs from below the ceiling in 1/2" or 5/8" ceiling material (may also be used in non insulated ceilings). Quick Connect wiring connectors included in junction box. Rated for 15 watts maximum. 13-1/4" length x 6-7/8" width x 7-1/2" height. Ceiling cutout: Match template supplied with housing - 6-1/4" typical. For use with 4" recessed lights. E27 socket. Use R20/PAR20 maximum 50 watt bulb (not included). Can be installed below the ceiling. For installations in non-insulated ceilings or where insulation can be kept 3" from housing. Integral thermal protector guards against misuse of insulation materials and improper lamping. Adjustable socket bracket allows the use of different lamp types and sizes as well as proper and consistent lamp positing. Junction box is listed for through branch circuit wiring and has seven 1/2" knockouts and four Romex knockouts with integral strain relief. Installation: 7-1/2" height allows use in 2 x 8 joist construction. Four remodel clips secure housing and accommodate ceiling thickness from 3/8" to 5/8". Requires ceiling opening per template. Listings: UL Damp Locations. UL Feed Through. CSA Certified. IP Rated.
Coilex Halo 410W Baffle Trim Powerzone RS2000R (MCN2) Recessed Light Fixture DWNLT IND RCSD 3000K LED 4IN
White trim ring with phenolic baffle, 7-1/4" OD, for use with 6" housings: Halo model numbers (Orgill SKU numbers), H7T (540.1815) and H7RT (942.0381). Non-IC housing, not for direct insulation contact; remodel housing applications. 4" downlight with E27 socket. Use R20/PAR20 50 watt maximum, (bulb not included). High brightness, diffusing, optical quality lens. Easy installation with universal mounting clips. Wet and damp location listed and IC (insulated ceiling) rated. Over 600 lumens. Compatible with 4" standard recessed housings: HALO?, ALL-PRO? and more. 50,000 hours with 70% maintained lumens. White plastic baffle trim.
Halo 30WAT Super Recessed Light Fixture Trim Powerzone 30002WH3L Recessed Light Fixture Cooper Lighting H7RICAT Recessed Lighting Housing
Self flanged socket supporting super trim AIR-TITE metal baffle with torsion spring construction, makes installation air-tite regardless of housing used. Prevents airflow between attic and living areas. 7-1/4" OD, for use with 6" housings: Halo model numbers (Orgill SKU numbers), H7T (540.1815), H71CT (552.4277), H71CAT (854.3951), H7RT (942.0381) and H7RICT (025.9697). White trim, white baffle, white reflector. Sleeved. Non-IC housing, 5" mini can with 7" white open trim. Built-in thermal protection. Prewired housing and electrical box. Takes PAR30 or R30 bulbs, 75 watt maximum, (not included). UL Listed for damp locations. cULus Listed. Cooper Lighting Recessed Lighting Housing, 120 VAC, Incandescent Lamp, Insulated Insulation, 6-1/2 in Ceiling, 6 in Diameter, UL, cUL Listed, CSA Certified
Halo H7 Remodel Recessed Housing Halo 78P Eyeball Recessed Light Trim Powerzone RS6000R+TRIM603-W Recessed Light Kit
Can be installed below ceiling. For installations where housing will be in direct contact with ceiling insulation. Integral thermal protector guards against improper lamping. Adjustable socket bracket assures proper and consistent lamp positing. Junction box is listed for through branch circuit wiring and has seven 1/2" knockouts and four Romex knockouts with integral strain relief. Installation: 7-1/2" height allows use in 2 x 8 joist construction. Four remodel clips secure housing and accommodates ceiling thickness from 3/8" to 5/8". Requires ceiling opening per template. Listings: UL damp locations. UL feed through. UL Listed for direct contact with insulation. CSA certified. IP rated. Wet location and AIR-TITE listed white trim with white eyeball 30 degree Tilt, 360 degree rotation, 8 "OD, for use with 6" housings: Halo model numbers (Orgill SKU numbers): H7T (540.1815), H71CT (552.4277), H71CAT (854.3951), H7RT (942.0381), H7RICT (025.9697) and SHALLOW H27T (989.1672). Sleeved. Use GU10, 50 watt maximum, (bulb included).
Powerzone 30001BK-3L Recessed Light Fixture Halo H99TAT Recessed Housing Halo H99RTAT Recessed Housing
Non-IC housing, 5" mini can with 6" white open trim and baffle. Built-in thermal protection. Prewired housing and electrical box. Takes PAR16, PAR20 or R20 bulbs, 75 watt maximum, (not included). UL Listed for damp locations. cULus Listed. Air-tite fixture sealed and gasketed to prevent airflow between attic space and living areas. The inner housing can be removed from plaster frame to provide access to the junction box. For providing accent and task lighting in non-insulated ceiling or where insulation can be kept 3" from housing. Thermal protector deactivates fixture if overheating occurs due to improper lamping or misapplied insulation. Junction box has four 1/2" trade size conduit knockouts with true pry-out slots. UL/cUL Listed Damp Location, Wet Location, feed through covered ceiling with select trims and 1598 Luminaire. Certified under ASTM-E283 for air tight construction. Air-tite fixture sealed and gasketed to prevent airflow between attic space and living areas. Can be installed from below the ceiling. For providing accent and task lighting where insulation can be kept 3" from housing. Thermal protector deactivates fixture if overheating occurs due to improper lamping or misapplied insulation. Junction box is listed for through branch circuit wiring and has seven 1/2" knockouts and four pryouts with integral strain relief for non-metallic sheathed cable. Four remodel clips secure housing and accommodate ceiling thickness of 1/2" and 5/8".  UL/cUL Listed 1598 Luminaire. UL/cUL Damp Location Listed. UL/cUL Listed for Wet Location, covered ceiling - with select trims. Certified Under ASTM-E283 for air tight construction.
   
 
1 2 3