Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL FITTINGS > NON METALLIC CABLE CONNECTORS
Sort By:
1
Halex 91530 Combination Coupling Halex 96510 2-Piece Butterfly Clamp Connector Halex 27511 Hit Lock Cable Connectors
Zinc die-cast. Use to join EMT conduit to non-metallic sheathed cable. #14/2, #12/3 or 2 #14/2. Indoor use only. UL approved. Zinc die-cast. In a dry location, use to secure #14 to #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required. Fits #14/2, #14/3, #12/2, #10/2, #10/3 NM cable. Snap-in, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL listed, CSA certified.
Halex 90513 Twin Screw Clamp Connector Halex 20511 Twin Screw Clamp Connector Halex 90514 Twin Screw Clamp Connector
Fits non-metallic cable #14/2 to #6/3 AWG or #3/10/3 AWG or flex cord 0.450 to 0.730 in Dia. With a 1/2 in knockout. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed, meets CSA requirements. Fits 1/2 in knockout, non-metallic cable #14/2, 12/2, 12/3 AWG or 2 #14/2 AWG or flex cord 0.3 to 0.56 in Dia. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed and meets CSA requirements. Fits non-metallic cable #6/3 to #2/3 AWG flex cord 0.800 to 1.350 in Dia or SE cable 3 conductor or 3 #1/0 minimum. 3 conductor or 3 #2/0 maximum. With 1/2 in knockout. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed, meets CSA requirements.
Halex 27519 Hit Lock Cable Connectors Halex 05115 Twin Screw Clamp Connector Halex 26512 2-Piece Butterfly Clamp Connector
Fits #14/2, #14/3, #12/2, #10/2, #10/3 NM cable. Snap-in, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL listed, CSA certified. Fits non-metallic cable, flex cords, multi flex cords. Fitting range 0.834 to 1.520 in Dia SE cables 2 conductor 4/0. With 1/2 in knockout. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed, meets CSA requirements. Tray boxed. Zinc die-cast. In a dry location, use to secure #14 to #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required.
Halex 05120 Twin Screw Clamp Connector Halex 20510 Twin Screw Clamp Connector Halex 75105B Hit Lock Cable Connectors
Fits non-metallic cable, flex cords, multi flex cords fitting range 1.085 to 1.520 in Dia. With 1/2 in knockout. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed, meets CSA requirements. Tray boxed. Fits 1/2 in knockout, non-metallic cable #14/2, 12/2, 12/3 AWG or 2 #14/2 AWG or flex cord 0.3 to 0.56 in Dia. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed and meets CSA requirements. Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified.
Halex 27515 Cable Connectors Halex 05103B Twin Screw Clamp Connector Halex 05112B Twin Screw Clamp Connector
Push-in style with captive locking wedge. Rigid PVC. Excellent strain relief and insulation. In a dry location, use to secure #14 to #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. Fits NM cable #14/2 to #10/3. Fits 1/2 in knockouts. UL, CSA listed. Fits 1/2 in knockout, non-metallic cable #14/2, 12/2, 12/3 AWG or 2 #14/2 AWG or flex cord 0.3 to 0.56 in Dia. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed and meets CSA requirements. Fits non-metallic cable #6/3 to #2/3 AWG flex cord 0.800 to 1.350 in Dia or SE cable 3 conductor or 3 #1/0 minimum, 3 conductor or 3 #2/0 maximum. With 1/2 in knockout. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed, meets CSA requirements.
Halex 05107B Twin Screw Clamp Connector Halex 05110B Twin Screw Clamp Connector Halex 05703B Combination Clamp Connector
Fits non-metallic cable, such as number 14/2 round, number 12/3 to 8/3 AWG or flex cord 0.460 to 0.720 in Dia. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed, meets CSA requirements. Fits non-metallic cable #14/2 to #6/3 AWG or number 3/10/3 AWG or flex cord 0.450 to 0.730 in Dia. With a 1/2 in knockout. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. UL listed, meets CSA requirements. Zinc die-cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8 in size fits 1/2 in knock outs. UL Approved.
   
 
1