Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE
Choose a sub category:
BUILDING WIRE / NM BUILDING WIRE / THHN BUILDING WIRE / UF
ENTRANCE CABLE ARMORED CABLE GROUND WIRE
LAMP CORD SJ CORD SPECIALTY WIRE
Sort By:
1 2 3 ... 7
Zenith AS110024C Speaker Wire Zenith AS105016C Speaker Wire Zenith AS105018C Speaker Wire
The Zenith 24 ga Speaker Wire, 100 ft provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. The Zenith 16 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. The Zenith 18 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity.
Zenith AS110018C Speaker Wire Romex SIMpull 14/2UF-W/GX25 Building Wire Armorlite 68579221 Type MC Armored Cable
The Zenith 18 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. Southwire Feeder Cable with Ground, Underground, 14 AWG Wire, 25 ft Length, 2 Conductors, Copper Conductor, PVC Sheath, Gray Sheath, 600 V, 90 deg C Operating Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.
Duraclad 55274921 Type MC Armored Cable Duraclad 55278321 Type MC Armored Cable Zenith AS105014C Speaker Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. The Zenith 14 ga speaker wire, 50 ft provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity.
Armorlite 68580021 Type MC Armored Cable Romex SIMpull 12/2UF-W/GX25 Building Wire Romex SIMpull 14/2NM-WGX25 Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Romex Building Wire, NM-B, 14 AWG Wire, 25 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Nylon Sheath, White Sheath, 600 V, 15 A, 90 deg C Operating
Southwire 22973236 THHN Building Wire Southwire 22974036 THHN Building Wire Southwire 22975736 THHN Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 22977336 THHN Building Wire Duraclad 55278521 Type MC Armored Cable Duraclad 55275021 Type MC Armored Cable
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Romex SIMpull 14/2UF-WGX50 Building Wire Romex SIMpull 12/2NM-WGX25 Building Wire Duraclad 55278322 Type MC Armored Cable
Romex Building Wire, UF-B, 14 AWG Wire, 50 ft Length, 2 Conductors, Strands per Conductor: 2, Copper Conductor, PVC Conductor Insulation, Stranded, Nylon Sheath, Gray Sheath, 600 V, 15 A, 90 deg C Operating Romex Building Wire, NM-B, 12 AWG Wire, 25 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Nylon Sheath, Yellow Sheath, 600 V, 20 A, 90 deg C Operating Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Duraclad 55274922 Type MC Armored Cable Armorlite 68579222 Type MC Armored Cable Armorlite 68583421 Type MC Armored Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.
Romex SIMpull 14/3NM-WGX25 Building Wire Southwire 22964152 THHN Building Wire Romex SIMpull 14/2NM-WGX50 Building Wire
Romex Building Wire, NM-B, THHN, 14 AWG Wire, 25 ft Length, 3 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 600 V, 15 A, 90 deg C Operating, Includes: Ground Wire Southwire Building Wire, THHN, 12 AWG Wire, 100 ft Length, 1 Conductors, Strands per Conductor: 19, Copper Conductor, PVC Conductor Insulation, Stranded, Nylon Sheath, Black Sheath, 0.13 in Sheath Diameter, 600 VAC, 20 A, 194 deg F Operating Romex Building Wire, NM-B, 14 AWG Wire, 50 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Nylon Sheath, White Sheath, 600 V, 15 A, 90 deg C Operating
Armolite 68580022 Solid Metal Clad Cable Romex SIMpull 12/2UF-WGX50 Building Wire SIMpull 22964151 THHN Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Southwire Building Wire, THHN, 12 AWG Wire, 50 ft Length, 1 Conductors, Strands per Conductor: 19, Copper Conductor, PVC Conductor Insulation, Stranded, Nylon Sheath, Black Sheath, 0.13 in Sheath Diameter, 600 VAC, 20 A, 194 deg F Operating
   
 
1 2 3 ... 7