Home > ELECTRICAL > HOUSEHOLD ELECTRICAL > HOUSEHOLD WIRING DEVICES > CORD ENDS-FEMALE 110V
Sort By:
1
Eagle SA155W Non-Grounded Spring Action Electrical Connector Eagle SA155B Spring Action Non-Grounded Electrical Connector Cooper Wiring SA155 Polarized Spring Action Cord Connector
General duty, made of high impact-resistant PVC and ABS thermoplastic for long-term durability. Clip provides cord grip for easy storage on appliances. Listed to UL 498 (file no.E15012), CSA Certified (file no.LR2081 (6221-02, 622182). NOM Certified. Meets flammability requirements per UL 94, VO rated. Temperature rating: -20 to + 60 deg C. NEMA 1-15. General duty, made of high impact-resistant PVC and ABS thermoplastic for long-term durability. Clip provides cord grip for easy storage on appliances. Listed to UL 498 (file no.E15012), CSA Certified (file no.LR2081 (6221-02, 622182). NOM Certified. Meets flammability requirements per UL 94, VO rated. Temperature rating: -20 to + 60 deg C. NEMA 1-15. Eaton Wiring Devices Electrical Connector, Polarized, Spring Action, 125 V, 15 A, 2 Pole, 2 Wires, 21/64 in Cable/Wire, Grounding Type: Non-Grounded, -20 to 60 deg C Operating, Thermoplastic, Black, Dimensions: 1.781 in L x 1.17 in W x 0.75 in D, NEMA 1-15
Cooper 4882-BOX Non-Grounded  Electrical Connector Cooper 86BK-BOX Non-Grounded Standard  Electrical Connector Cooper Wiring SA993W Spring Action Straight Body Cord Connector
Commercial-grade vinyl connectors solid brass plug blades are firmly embedded in body. Terminal screw clamps are designed to contain wire and prevent binding. Terminal screws backed out ready for wiring. Terminals in individual chambers to positively insulate conductors. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. General duty, meets all UL 498 requirements. Terminals in individual chambers to positively insulate conductors. 15 A, 125 V. 21/64 in cord diameter. NEMA 1-15. Eaton Wiring Devices Electrical Connector, Spring Action, 125 V, 15 A, 2 Pole, 3 Wires, 21/64 in Cable/Wire, Grounding Type: Grounded, -20 to 60 deg C Operating, Thermoplastic, White, Dimensions: 2-1/4 in L x 1-7/16 in W x 3/4 in D, NEMA 5-15
Eagle SA993 Grounded Polarized Standard  Electrical Connector Cooper SA9930 Grounded Straight Electrical Connector Arrow Hart 222-BOX General Duty  Electrical Connector
Standard-grade. Meets all UL 498 requirements. Terminals in individual chambers to positively insulate conductors. 15 A, 125 V. 21/64 in cord diameter. Straight, NEMA 5-15. Thermoplastic grounding connectors tough thermoplastic construction. Plug blades are firmly embedded in body. Meets all UL 498 requirements. Terminals in individual chambers to positively insulate conductors. Combination slot/Phillips head mounting and terminal screws. UL listed, CSA certified. Not NOM certified.
CONNECTOR EZKLAMP GROUND      Cooper 4887 Electrical Connector Eagle 6887-BOX Grounded Polarized  Electrical Connector
Standard-grade. Meets all UL 498 requirements. Terminals in individual chambers to positively insulate conductors. 15 A, 125 V. 5/16 in cord diameter. Straight, NEMA 5-15. Terminals in individual chambers to positively insulate conductors. Terminal screw clamps are designed to contain wire and prevent binding. Terminal screws backed out, ready for wiring. Nylon Kwiklok features patented twist-actuated internal cord clamp, reduces installation time. Meets all UL 498 requirements. Yellow color. Standard-grade. Meets all UL 498 requirements. Terminals in individual chambers to positively insulate conductors. 15 A, 125 V. NEMA 5-15. UL listed.
Cooper 2887 Grounded Electrical Connector Cooper BP4887  Electrical Connector Cooper 4228-BOX Grounded  Electrical Connector
Armored housing automatically grounded. Combination slot/Phillips head mounting and terminal screws. Terminal screw clamps. Fits Cooper plug number 2867, Orgill SKU 444.9625. 15 A, 125 V. NEMA 5-15 configuration. UL listed, CSA and NOM certified. Terminals in individual chambers to positively insulate conductors. Terminal screw clamps are designed to contain wire and prevent binding. Terminal screws backed out, ready for wiring. Nylon Kwiklok features patented twist-actuated internal cord clamp, reduces installation time. Meets all UL 498 requirements. Yellow color. Terminals in individual chambers to positively insulate conductors. Terminal screw clamps are designed to contain wire and prevent binding. Terminal screws backed out, ready for wiring. Nylon Kwiklok features patented twist-actuated internal cord clamp, reduces installation time. Meets all UL 498 requirements. Yellow color.
CONNECTOR BLD STRT LED YEL 15A Arrow Hart Hart-Lock Safety Grip L520C Cooper 3487-4GN High Visibility Straight Electrical Connector
Eaton's lighted plugs and connectors offer added piece of mind by illuminating an LED when power is flowing through the device. Our plugs and connectors are compact yet rugged for virtually any replacement application or do-it-yourself extension cord creation. Abuse-resistant thermoplastic construction. External cable clamp provides firm strain relief. Back wire terminal clamps for easy secure wiring. Triple combination head screws standard - Slot/Phillips/Robertson for use in the US and Canada. 1/4 to 11/16 in cord Dia. Highly visible and easy to locate at the job sight. Molded out of impact-and chemical-resistant nylon. Neoprene gasket seals cord opening to protect against moisture, dirt, wood chips and more. Temperature rating of -40 to 75 deg C. 15 A. UL 498 listed (file #E15012), CSA Certified C22.2 #42 (file #2081) (6221-02) NOM Certified. NEMA 5-15. Carded.
Cooper 3487-4RN High Visibility Straight Electrical Connector Arrow Hart Autogrip Eagle 5269 Grounded Electrical Connector Arrow Hart Hart-Lock Safety Grip L530C
Highly visible and easy to locate at the job sight. Molded out of impact-and chemical-resistant nylon. Neoprene gasket seals cord opening to protect against moisture, dirt, wood chips and more. Temperature rating of -40 to 75 deg C. 15 A. UL 498 listed (file #E15012), CSA Certified C22.2 #42 (file #2081) (6221-02) NOM Certified. NEMA 5-15. Carded. Industrial-grade. High impact-resistant thermoplastic housings with easy-grip grooves. Plated steel assembly screws are speed-threaded and captive, reducing installation time. Terminals in individual chambers to positively insulate conductors. Clearly marked rating, NEMA configuration and standard compliances (third-party listing) on face of device. Color-coded clamps identify amperage - blue 15 A. Terminal screws backed out; ready for wiring. Combination slot/Phillips head terminal, assembly and clamping screws. Meets all 498 requirements. 15 A, 125 V. UL listed. NEMA 5-15. Abuse-resistant thermoplastic construction. External cable clamp provides firm strain relief. Back wire terminal clamps for easy secure wiring. Triple combination head screws standard - Slot/Phillips/Robertson for use in the US and Canada. 1/4 to 11/16 in cord Dia.
Super Spec WD4729 Grounded Twist-Lock Electrical Connector Cooper Wiring Hart Lock Safety Grip Polarized Locking Connector Arrow Hart 15W47-K Grounded  Watertight Electrical Connector
Abuse-resistant thermoplastic construction. External cable clamp provides firm strain relief. Back wire terminal clamps for easy secure wiring. Triple combination head screws standard - Slot/Phillips/Robertson for use in the US and Canada. 1/4 to 11/16 in cord Dia. Eaton Wiring Devices Electrical Connector, Locking, Safety Grip, Straight Body, 125/250 V, 15 A, 2 Pole, 3 Wires, 21/64 to 21/32 in Cable/Wire, Grounding Type: Grounded, -40 to 75 deg C Operating, Nylon, Black/White, Dimensions: 3-7/8 in L x 1-1/2 in W, NEMA L5-15 Used for marine applications in areas of water or moisture. Thermoplastic elastomeric (TPE) exterior. Glass filled nylon and glass filled polypropylene interior. 15 A, 125 V. Temperature rating of -40 to 70 deg C. Listed to UL 498 (file no.E3663) and watertight. NEMA 5-15.
Cooper WD8269  Electrical Connector Arrow Hart 224-BOX Non-Grounded  Electrical Connector
Hospital-grade. Meets all UL 498 requirements. High-impact resistant thermoplastic housing. See-through terminal cover allows inspection of connections. NEMA construction and standard compliances. Color-coded clamps. 15 A, 125 V. Boxed. Standard-grade. Connectors meet all UL 498 requirements. Resists chemical attack and stays flexible in extremely low temperatures. Polypropylene, PVC and thermoplastic rubber. Meets flammability requirements per UL 94. 15 A, 125 V. -20 to +70 deg C. NEMA 1-15. Boxed.
   
 
1