Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > ENTRANCE CABLE
Sort By:
1
CBL ENTR SERV 2-2-2AWG 3C 100A CBL ENTR SERV 4/0-4/0-4/0AWG CBL ENTR SERV 6-6-6AWG 150FT
Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 deg C in wet or dry locations, 600 V. UL listed. Amp capacities listed are at 30 deg C/85 deg F. Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 deg C in wet or dry locations, 600 V. UL listed. Amp capacities listed are at 30 deg C/85 deg F.
CBL ENTR SERV 8-8-8AWG 250FT CBL ENTR SERV 2-2-4-6AWG 500FT CBL ENTR SERV 4-4-4AWG 150FT
Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 deg C for dry locations or 75 deg C for wet locations, 600 V. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight- and moisture-resistant, flame retardant jacket. UL listed. Amp capacities listed are at 30 deg C/85 deg F. Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact Stranded 8000 Series aluminum alloy. 600 V. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 deg C. Quadruplex cable conductor construction. UL listed. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 deg C for dry locations or 75 deg C for wet locations, 600 V. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight- and moisture-resistant, flame retardant jacket. UL listed. Amp capacities listed are at 30 deg C/85 deg F.
CBL ENTR SERV 4/0-4/0-2/0-4AWG
Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact Stranded 8000 Series aluminum alloy. 600 V. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 deg C. Quadruplex cable conductor construction. UL listed.
   
 
1